Hetzner Online
Competitive edge
In Hetzner Online's Colocation Center, customers are able to connect their own hardware to Hetzner Online's infrastructure and network. With over 20 years of expertise and as one of the most successful web hosting providers and data center operators in Europe, we at Hetzner Online build our data center parks with efficient designs. Our 20 data centers prove that we know how to scale. We have grown our own infrastructure quickly, and we can advise you on how to best scale up your operations, too.
To ensure that customer data is always safe and sound, Data Center Park Helsinki, like all Hetzner data centers, employs a redundant power supply system, optimal temperature conditions (using direct free cooling), early warning fire alarms, and a team of 24/7 support technicians. And naturally, access to the data centers themselves is very restricted.
In addition, our efficient climate concept, which uses wind power, protects not only your wallet but also the environment. We invested in the C-Lion cable, which stretches from Helsinki to Rocktock, Germany, enabling our customers to profit from a speedy gateway to markets in Central, Eastern, and Western Europe, as well as Asia and beyond.
Incoming capacity with extensions (mva)
1Redundancy and options
Redundant power supply via A/B line or via 63A protected circuits
Backup generators
Diesel generators
Ups capacity
1200 kW
Notes on power solutions
Power supply via two separate power paths from the substation to the low-voltage distribution
Type of cooling
AirPue (monthly and annual average)
1.2Redundancy
N+2
Notes on cooling solutions
- Direct free cooling (ambient air)
- Cold aisle containment or climate control via raised floors
Connectivity service providers
Elisa Oyj
DNA Oyj
Notes on colocation connectivity services
Provider-independent colocation space
Surveillance systems
- Data center parks are completely and continuously monitored (video surveillance)
- Manned 24/7/365 by on-site qualified staff
Physical security
Special door and interlocking systems, identity checks
Access controls
24/7 access via transponder controlled security doors
Type of fire protection systems
Early warning fire system:
- Smoke detection pipes both under the raised floor and ceiling in Data Center
- Fire brigade response time around 15 min from alarm
Racks and suites
- 1/3 Racks (14 unit rack space in a 19" rack )
- Rack Advanced (47 unit rack space in a 19" rack )
- Cages from 20 square meters
White space
2,000 square meters
Remote hands services
Available
Network services
1G/10G internet uplinks (redundancy available if necessary)
Cyber security
Protected network through DDoS protection